Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Vascular Specialist International ; : 34-38, 2019.
Article in English | WPRIM | ID: wpr-762003

ABSTRACT

Iliac artery aneurysms are usually asymptomatic. Herein, we report a novel strategy for the repair of a pseudoaneurysm involving the external iliac artery using a conventional artificial graft and bare metal stent. A 76-year-old male patient presented with severe resting pain and right foot discoloration. Computed tomography angiography revealed a right distal external iliac artery pseudoaneurysm, with severe calcified occlusion at the right common and superficial femoral arteries. After exposing the right femoral artery, long-segment endarterectomy and patch angioplasty with the ipsilateral greater saphenous vein were performed. Before the completion of patch angioplasty, a surgeon-modified 8-mm expanded polytetrafluoroethylene (ePTFE) graft was inserted for complete pseudoaneurysm repair. If a commercial covered stent is not available, minimally invasive endovascular repair can be safely performed using a surgeon-modified ePTFE graft and bare metal stent.


Subject(s)
Aged , Humans , Male , Aneurysm , Aneurysm, False , Angiography , Angioplasty , Endarterectomy , Femoral Artery , Foot , Iliac Artery , Polytetrafluoroethylene , Prostheses and Implants , Saphenous Vein , Stents , Transplants
2.
Clinics ; 65(12): 1315-1323, 2010. graf, tab
Article in English | LILACS | ID: lil-578571

ABSTRACT

OBJECTIVES: A duplex ultrasound study was performed to investigate morphological and hemodynamic patterns of carotid stenoses treated by endarterectomy with patch closure versus stenting. MATERIALS AND METHOD: Twenty-nine carotid stenoses were treated with stenting and 65 with patch closure. Duplex ultrasound parameters (luminal diameter, mm; peak systolic velocity and end-diastolic velocity, cm/s) were measured 24 hours after the procedures and also at 12 months post-procedure. Residual stenoses (immediately postprocedure) and restenoses (within 12 months of procedure) were defined as narrowings of >50 percent on duplex ultrasound examination. RESULTS: In stented patients, the luminal diameter of the proximal internal carotid artery increased in the interval between the 24-hour and 12-month post-procedure studies, while in the patch closure patients, the diameter decreased. Carotid hemodynamics normalized immediately after both patching and stenting and remained relatively stable thereafter up to 12 months. No statistically elevated flow velocities (in the absence of residual stenosis or restenosis) were observed in the patched or stented carotid arteries. No significant differences in residual stenosis rates were observed between the stenting group (3 cases, 10.34 percent) and the patch closure group (1 case, 1.53 percent, P = 0.08). At 12 months, 2 stenting patients (6.88 percent) and 2 patch closure patients (3.07 percent) had $50 percent restenosis (P = 0.58). One case of late stroke due to restenosis was observed in the stenting group; the patient died 12 months postoperatively, before receiving new intervention. CONCLUSION: Measurements over time in luminal diameter signalized differences in arterial remodeling mechanisms between patched and stented carotids. Both stenting and patch closure were associated with carotid patency and flow restoration. This study does not support a general approach to new velocity criteria indiscriminately applied to stented or patched carotids.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Carotid Artery, Internal , Carotid Stenosis , Endarterectomy, Carotid/methods , Hemodynamics/physiology , Blood Vessel Prosthesis , Chi-Square Distribution , Carotid Artery, Internal/physiopathology , Carotid Artery, Internal/surgery , Carotid Stenosis/physiopathology , Carotid Stenosis/surgery , Stents , Treatment Outcome , Ultrasonography, Doppler, Duplex
SELECTION OF CITATIONS
SEARCH DETAIL